Coolsculpting Harley Street Clinic London Private Testing

Harley Street Treatments Private Covid19 Testing Liposuction Coolsculpting

  • Home
    • Covid Variants
  • Cosmetic Surgery
  • Dentists
  • Doctors
  • Treatments
    • Hospitals
    • Baldness & Hair Loss
    • Botox Treatment
    • Colonic Irrigation
    • Dermal Fillers
    • Diabetes Insulin Pumps
    • Harley St Clinic FUE Baldness Hair Loss
    • i-lipo
    • Laser Liposuction Harley Street Clinic London
    • Laser Hair Removal
    • Transosseous Teeth Implants
    • Coolsculpting London Harley Street
  • Contact
    • Sitemap
    • Blog
    • Location

Diabetes Insulin Pumps

A range of Harley St Doctors offers access to diabetes insulin pumps.

Many patients struggle to obtain insulin pumps on the NHS but these are easily available via a range of Harley St diabetes clinics.

The most recently available advance in insulin delivery is the insulin pump.  An insulin pump is composed of a pump reservoir similar to that of an insulin cartridge, a battery-operated pump, and a computer chip that allows the user to control the exact amount of insulin being delivered.

 

How big is an insulin pump?

 Currently, pumps on the market are about the size of a standard communications beeper.

 

How does an insulin pump work?

 The pump is attached to a thin plastic tube (an infusion set) that has a soft cannula (or plastic needle) at the end through which insulin passes. This cannula is inserted under the skin, usually on the abdomen. The cannula is changed every two days. The tubing can be disconnected from the pump while showering or swimming. The pump is used for continuous insulin delivery, 24 hours a day. The amount of insulin is programmed and is administered at a constant rate (basal rate). Often, the amount of insulin needed over the course of 24 hours varies depending on factors like exercise, activity level, and sleep.

The insulin pump allows the user to program many different basal rates to allow for variation in lifestyle. In addition, the user can program the pump to deliver a bolus (large dose of insulin) during meals to cover the excess demands of carbohydrate ingestion.

 

How common is an insulin pump?

 Over 50,000 people with diabetes worldwide are using an insulin pump. This number is growing dramatically as these devices become smaller and more user-friendly. Insulin pumps allow for tight blood sugar control and lifestyle flexibility while minimizing the effects of low blood sugar (hypoglycemia). At present, the pump is the closest device on the market to an artificial pancreas. More recently, newer models of the pump have been developed that do not require a tubing, in fact – the insulin delivery device is placed directly on the skin and any adjustments needed for insulin delivery are made through a PDA like device that must be kept within a 6 foot range of the insulin delivery device, and can be worn in a pocket, kept in a purse, or on a tabletop when working.

Probably the most exciting innovation in pump technology is the ability to use the pump in tandem with newer glucose sensing technology. Glucose sensors have improved dramatically in the last few years, and are an option for patients to gain further insight into their patterns of glucose response to tailor a more individual treatment regimen. The newest generation of sensors allows for a real time glucose value to be given to the patient. The implantable sensor communicates wirelessly with a pager-sized device that has a screen. The device is kept in proximity to the sensor to allow for transfer of data, however, it can be a few feet away and still receive transmitted information. Depending on the model, the screen displays the blood glucose reading, a thread of readings over time, and a potential rate of change in the glucose values. The sensors can be programmed to produce a “beep” if blood sugars are in a range that is selected as too high or too low. Some can provide a warning beep if the drop in blood sugar is occurring too quickly.

To take things one step further, there is one particular sensor that is new to the market that is designed to communicate directly with the insulin pump. While the pump does not yet respond directly to information from the sensor, it does “request” a response from the patient if there is a need for adjustments according to the patterns it is programmed to detect. The ultimate goal of this technology is to “close the loop” by continuously sensing what the body needs, and then responding by providing the appropriate dose of insulin. While this technology is a few more years in the making, the strides in this direction continue to grow.

 

Recent Posts

  • Private Booster Jabs Covid
  • RyanAir Fit to Fly Test
  • Sigma Variant Covid 19 New Variant Strain of Concern
  • Omicron Variant – Covid 19 New Variant of Concern
  • Private Covid-19 PCR Tests Fit Fly Travel Abroad
Patient Care

Harley Street Hospitals and Clinics

There are a wide range of private hospitals and Harley St Clinic that cover a range of treatment such as cosmetic surgery, IVF clinics, laser eye treatments, dental clinics and diabetes clinics.

Search our comprehensive guide to the vast array of Clinics and
Harley St Doctors Clinic on Harley Street.

Search Harley Street Clinics

Contact Us

  • This field is for validation purposes and should be left unchanged.

Medical News

  • Private Booster Jabs Covid
  • RyanAir Fit to Fly Test
  • Sigma Variant Covid 19 New Variant Strain of Concern
  • Omicron Variant – Covid 19 New Variant of Concern
  • Private Covid-19 PCR Tests Fit Fly Travel Abroad
  • Private London Club Offers Covid Vaccines Abroad
  • ETA Variant Covid 19 Coronavirus
  • PCR Test London Free
  • Covid Booster Shots
  • Epsilon Variant Covid Coronavirus Vaccine
©2021 Harley-Street-Clinic.com| Sitemap | Credits | Contact | Privacy Policy | Harley Street Clinic, Harley Street, London SW1 1AA